AC Surge Protector (SPD)Manufacturer

AC surge protection device (SPD) types
Palm series single-phase/three-phase AC surge protector
Type 1 Surge Protector (SPD)
Type 1 Surge Protector (SPD)
Palm series single-phase/three-phase type 1 ac surge protector
The key parameters of Type 1 surge protector include: surge current Iimp, maximum continuous operating voltage Uc, voltage protection level Up, and response time tA. These parameters are crucial for evaluating and selecting the performance of surge protectors.
Specification parameters:
◆ Type 1/T1/Class B
◆ Nominal voltage Un: 230V 400V
◆ Max. continuous operating voltage Uc: 275V/320V/385V/440V
◆ Nominal discharge current (8/20 μs) In = 25kA Type 2
◆ Impulse discharge current (10/350 μs) Iimp = 25kA Type 1
◆ Maximum discharge current (8/20 μs) Imax = 100kA Type 2

Wiring Diagram & Installation
Palm series single-phase/three-phase type 1 ac surge protector

Type 1+2 Surge Protector (SPD)
series single-phase/three-phase type 1+2 ac power surge protector
Whether it is a 1+2 type surge protector or a simple 1 or 2 type surge protector, a lower voltage protection level is important to achieve lightning protection.
Type 1+2 ac power surge protector LKX-C40/B+C For three-phase TN-S systems
Type 1+2 ac power surge protector LKX-C40/B+C For single phase TN-S, TN-C, TT
Type 1+2 ac spd power surge protector LKX-B+C For single phase TN-S systems
Type 1+2 ac power surge protector LKX-C40B+C For single phase TN-S systems
Type 1+2 Surge Protector (SPD)
Palm series single-phase/three-phase ac spd type 1+2 surge protector

Type 2 AC Surge Protector (SPD)
Palm series single-phase/three-phase type 2 ac surge protector
Type 2 surge protectors are usually installed at the lightning protection boundary between LPZ1 and LPZ2 zones or beyond, such as floor distribution boxes, meter boxes, or terminal boxes. Its main purpose is to further protect critical or sensitive electrical equipment by limiting voltage to prevent transient overvoltage from causing damage to the equipment. The Type 2 surge protector should be a voltage limiting type, with a lightning current capacity of not less than 20KA. It should be installed at critical or sensitive electrical equipment to absorb more of the remaining surge and have good suppression effect on transient overvoltage.
Type 2 Surge Protector (SPD)
Palm series single-phase/three-phase type 2 ac power surge protector

AC surge protector dimensions
Palm series single-phase/three-phase type 2 ac power surge protector